1 / 1
Basic Info
| Model No. | YJV |
|---|---|
| Brand Name | Taifa |
Product description
?
Medium voltage COPPER? power cable 22KV?
?
1). Standard: IEC60502; GB12706.1-2002
2) Specification: Circular Copper conductor for single core and shaped conductors for muti-core, XLPE insulated, PVC bedding, armored(or unarmored) PVC sheathed cable.
?
Detailed description or construction:
??? * Conductor: compacted or uncompacted copper or aluminium
??? * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
??? * Filler: Polypropylene filament with lapped binding tape
??? * Binder: Binding tape
??? * Inner sheath: Polyvinyl chloride (PVC)
??? * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
??? *Sheath: Polyvinyl chloride (PVC)
?
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
????????U0/U(Um) =3.6/6(7.2)-6/10(12)-8.7/15(17.5)-12/20(24)-18/30(36)-21/35(40.5)KV
???In the voltage designation of cables U0/U(Um):
??????? * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
??????? * U is the rated power frequency voltage between conductors for which the cable is designed;
??????? * Um is the maximum value of the "highest system voltage" for which the equipment maybe used
?
4) Voltage:0.6/1kv,6/6kv,6/10kv,8.7/15kv,12/20kv,18/30kv,19/33kv,26/35kv
?
5). Application:used in ducts, trays and direct burial in ground. the cable is subjuct to immerse in water all the time.
?
?
6).This series includes:Single copper(Alumunium) core XLPE insulated PVC sheated
????* Single copper(Alumunium) core XLPE insulated??steel tape armoured?PVC sheathed
??? * Single copper(Alumunium) core XLPE insulated steel wire armoured PVC sheateed
????* Multi-core copper(Alumunium) core XLPE insulated PVC?PVC sheath
??? * Multi-core copper(Alumunium) core XLPE insulated PVC?inner sheath steel tape armoured PVC? sheath
??? * Multi-core copper(Alumunium) core XLPE insulated PVC??inner sheath steel tape armoured?PVC sheath
?
7).Product feature
??? a.Max Long-time operating temperature of XLPE insulated cable is 90(70)°C.
????b.Installing temperature of cable should not be less than 0°C.
??? c.Max short-circuit temperature is not exceed 250(160)°C, not more than 5 sec.
?
8). Marking: According to the customers' requirements
?
9).Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
?
?
type |
No. of cores |
0.6/1 KV |
6/6KV 6/10KV |
8.7/15KV 12/20KV 18/30KV |
19/33KV 26/35KV |
mm2 | |||||
Copper/XLPE/PVC |
1 |
1.5-800 |
25-800 |
35-1200 |
50-1200 |
Aluminum/XLPE/PVC |
2.5-1000 |
25-1000 |
35-1200 |
50-1200 |
|
Copper/XLPE/SWA/(STA,SWA)PVC |
10-1000 |
25-1000 |
35-1200 |
50-1200 |
|
Copper/XLPE/PVC |
3 |
1.5-400 |
25-400 |
35-400 |
50-400 |
Aluminum/XLPE/PVC |
2.5-400 |
25-400 |
35-400 |
50-400 |
|
Copper/XLPE/SWA/PVC |
4-400 |
25-400 |
35-400 |
50-400 |
|
?
?
?
?
Send your inquiry to this supplier