Mounting Note:
?
1)Use a heat sink (accessory) to protect solid state relays, and the heat sink must be grounded.
2)Must install quick fuse.
3)Radiator must choose correct model according to the work-environment temperature and load current.
4)Contact distance between the heat sink and rediator should not be greater than 0.05mm when you install the radiator?the rough degree should not be greater than 0.02mm.
Note:
1)It can ensure the thermal conductivity without impurities using a gram of thermal Grease to paint on metal surface of heat sink.
2)Tightening up the 2 nuts in turn,the M4 nut torque of 1.2 NM , the M5 nut torque of 0.75M.
?
3)Suggest that open check whether the normal installation, ensure the metal coating and heat conduction layer without bubbles.

?