1 / 1
Basic Info
| Model No. | T-910 |
|---|
Product description
|
Model?Number |
?TENGCON?T-910??(8AI,2AO,12DI,8DO)??ethernet controller |
||
|
Physical?Feature | |||
|
Dimension |
169?x?134?x?63?mm?(W?x?H?x?D) |
||
|
Weight |
0.5?Kg |
||
|
Mount |
Standard?rail?or?bolts |
||
|
Working?Temperature |
From?-40oC?to?85?oC |
||
|
I/O?Feature | |||
|
Built-in?digital?inputs |
12??(Optical?coupling?isolated?input,?2?of?them?can?be?used?as?high-speed?counters) |
||
|
Built-in?digital?outputs |
8??(Relay?output) |
||
|
Built-in?analog?inputs |
8??(0-20mA?or?0-5V) |
||
|
Built-in?analog?outputs |
2??(0-20mA?or?0-10V) |
||
|
Built-in?high-speed?impulse?counters |
2?single-phase?or?1?two-phase?(100?KHz?impulse?counting,?can?be?used?as?2?single-phase?or?1?two-phase) |
||
|
I/O?state?indicators |
44?pcs. |
||
|
Input?image |
256?Byte?(512?bits?for?digital?inputs?and?192?Byte?for?analog?inputs) |
||
|
Output?image |
256?Byte?(512?bits?for?digital?outputs?and?192?Byte?for?analog?outputs) |
||
|
Power?Supply?and?power?output | |||
|
Power?Supply |
Rated?Voltage |
220V?AC?or?24V?DC |
|
|
Range |
From?90V?AC?to?250V?AC,?50Hz,?or?24V?DC |
||
|
Rated?current |
140mA/90VAC(when?all?the?digital?outputs,?analog?outputs?and?24V?DC?output?in?full-load) 40mA/220VAC(when?all?the?digital?outputs,?analog?outputs?and?24V?DC?output?in?full-load)? 23mA/220VAC(when?all?the?digital?outputs?and?analog?outputs?in?full-load,?but?24V?DC?output?in?no-load) 14mA/220VAC(when?all?the?digital?outputs,?analog?outputs?and?24V?DC?output?in?no-load) |
||
|
Isolated?power?output |
Rated?voltage |
24VDC |
|
|
Rated?current |
0.2A |
||
|
Output?resistance |
About?20?Ohm |
||
|
Terminals |
VOUT(24V+,?24V-) |
||
|
Communication? | |||
|
Ethernet |
1?port??(RJ45,?10M/100M?adaptive,MODBUS?TCP?protocol) |
||
|
RS232 |
1?port??(COM0,?for?internal?test) |
||
|
RS232/485 |
3?port? l?COM2,?DB9?RS232?direct?connect l?COM1,?DB9?RS485(pin?2?is?B,?pin?3?is?A) l?COM3,?DB9?RS485(terminal?AB) Default?settings:?MODBUS?RTU?Slave,?Bode?rate?19200,1,8,E,?address?1 |
||
|
DIP |
8-bits? Set?DIP?ON?will?force?the?IP?address?to?the?default 192.168.1.99 |
||
|
Run/stop?switch |
2?switches? run/stop(in?stop?mode,?only?PLC?program?stopped) |
||
|
Communication?indicator |
6?pcs.? l?RUN?indicator(flashing) l?COM1?COM2serial?port?communication?indicator(flashing?when?communicating) l?LINK?Ethernet?linking?indicator DATA?Ethernet?communicating?indicator |
||
|
Memory | |||
|
User?program?memory?size |
2M?Byte |
||
|
User?data?memory?size |
2M?Byte |
||
|
Back-up?battery?data?memory |
1K?Byte |
||
|
Data?back-up?time |
1?year |
||
|
CPU?feature | |||
|
CPU?frequency |
48?MHz |
Max.?72?MHz |
|
|
Minimum?instruction?processing?time |
4?millisecond |
? |
|
|
INT?and?Bit?operation |
From?1?to?4?microsecond |
? |
|
|
Floating-point?algorithm |
About?40?microsecond |
? |
|
|
1ms?timer?quantity? |
No?limit |
? |
|
|
Clock |
Internal?clock |
Back-up?battery |
|
|
Working?Power?Supply |
220V?AC?50HZ? |
Please?confirm?which?one? |
|
9-36V?DC | ||
|
DC?input |
0-20MA(default?setting) |
Please?confirm?which?one |
|
0-5V?? | ||
|
DC?output |
0-20MA(default?setting) |
Please?confirm?which?one |
|
0-10V | ||
|
DI?Voltage |
24V/DC |
? |
|
Communication |
2?RS485?port,1RS232?port?(default?setting) |
Please?confirm?which?one |
|
? |
3?RS485?port |
|
|
Quantity |
? |
|
Send your inquiry to this supplier