Accuracy class
0.02%/0.05%
Product Overview
GF333V2
meter, developed by our company, is a standard electric energy meter with
characteristics of wide-range, multifunction and high-precision. It has accuracy
grade of 0.02. By adopting techniques of DSP, embedded system and automatic
temperature balancing and other compensation, it has not only advantages of
light weight, small size, high precision, high performance, powerful function,
original interface, ease-to-use, but also work stability.
The product
can be widely used in fields of electric energy measuring, electric energy
laboratories and other relevant industry, not only in laboratories but also at
the industrial field.
Functions and
Features
1. With
cases of luxury sectional bar, A-series has a luxurious appearance. While with aluminum
cases, B-series is portable, more smaller (it is the smallest one in domestic
products of this kind. 355*145*185mm) , more lighter and easier to take.
2.
Wide-range measuring:
Voltage
measuring range (phase voltage):1~560V
Current measuring range: 10mA~120A
3.
Measurement of various ways: It has ability to measure AC voltage , current ,
power (active power, reactive power, apparent power) and electric energy in
four-quadrant with connection modes such as single-phase and four-wire
three-phase Y/ three-wire Δ. In addition, it can measure reactive power and
electric energy with ways of true reactive, cross-phase reactive power,
artificial neutral point of reactive.
4.
Multifunctional measurement:
-
Fundamental function of measuring for
voltage, current, phase, frequency, active power, reactive power, power factor
and error.
-
Measuring
degree of stability of voltage, current and power.
-
Measuring
degree of asymmetry of voltage and current amplitude in three-phase
circuits.
-
Measuring
degree of unbalancedness of voltage and current in three-phase
circuits.
-
Measuring
degree of asymmetry of the phase.
-
vector
diagram. There are a variety of display ways for
vector diagram to meet the different display habits (such as clockwise rotation,
counterclockwise rotation; the choice of the benchmark location between 12:00
o`clock and 3:00 o`clock; reference benchmark can be changeable; phase settings
for display ways: 0~360°or±180°).
-
Waveform
display, harmonic analysis, distortion calculation. Display of frequency spectrum, it can
display the amplitude, contents and phase of the harmonic. Frequency spectrum
can be enlarged.
-
Dem
measurement.
-
Measurement of space magnetic induction
intensity.
-
Measurements of voltage drop of the device`s
dotted terminal.
-
Measurement of the constant and frequency of
the meter to be adjusted.
-
Measurement of power of fundamental
wave.
-
It can
adjust errors of three different kinds of meters (active power, reactive power,
apparent power, voltage, and current).
-
There are
three ports for pulses to output. And its constants can be set automatically or
manually. Types of constants can be set also: active power, reactive power,
apparent power, voltage, and current.
-
It can
check the comprehensive error of device composed of three single-phase
meters.
-
It can be
used as three single-phase standard meters.
5.
Measurement of power for fundamental wave: not only could it measure the full
power (including powers of fundamental wave and orders harmonics), but also the
fundamental power only.
6.
Adjustment of electric energy error: it can adjust the estimate value of
standard deviation and computation error of electric energy meters as well as
calibration device for energy meter. Moreover, counts of pulse and constants of
meters to be checked can be set automatically so as to work effectively.
Especially for the multi-constant standard meter and the energy meter
calibration device, it will be more convenient. By adopting the use of special
compensation techniques, error-beating would not be large because of the small
load (the low frequency of the energy pulses). It can display the current error,
the value of the standard deviation estimate and the average error.
7. Harmonic
analysis: it can analyze the harmonics of voltage and current under 51
orders.
8. Display
of data and graphics: it can display the measuring working condition and
multiple measuring data directly. It can also display the waveform of the
voltage and current to be measured, the phase vector graph of the voltage and
current and waveform of harmonic analysis directly.
9. The
measuring range can be switched manually or automatically.
10. With
storage function, it can store 30 groups of data records which can be searched
and browsed according to the condition.
11. With
the function of Pinyin input method: Chinese Character, alphabet and symbol can
be inputted.
12.
Connection: the input port of the wide-range current is a public port, and there
is no need to change connection mode while the current is changed, so it is very
convenient to use.
13.
Multi-use: it can be used as a standard-meter, also as
a calibration device for energy meter. It can be used alone, with PC by remote
communication, also with calibration device.
14.
Multiple ports for communication: RS485, RS232, USB, and baud rate can be set
when using asynchronous communication.
15. With
6.4(or 5.7)-inch 640*480 pixel TFT display, it shows
clearly and colorfully.
16.
Operation: human orient design, reasonable combination of the function and
simple operating.
Specification
-
Current measurement
(Actual valid value RMS)
Range: 0.2A,1A,5A,20A,100A, angle switch
automatically
Display range: 00000mA~120.000A
Measurement error:distorted
wave:±0.02%RD(10mA~120A)
Fundamental:±0.02%RD(10mA~120A)
2~21
harmonic:±0.1%RD(10mA~120A)
Measurement time base:1s~99s
-
Voltage measurement
(Actual valid value RMS)
Range:60V,120V,240V,480V range switch
automatically
Display range:0.00000V~576.000V
Measurement
error:
distorted
wave:±0.02%RD(40V~576V)
Fundamental:±0.02%RD(40V~576V)
2~21
harmonic:±0.1%RD(40V~576V)
Measurement time base:1s~99s
-
Power measurement
Measurement error:
Distorted wave active power:±0.02%
RD(40V~576V,10mA~120A,PF≥0.5)
Sine wave reactive power:±0.02%
RD(40V~576V,10mA~120A,PF≥0.5)
Sine wave apparent power:±0.02%
RD(40V~576V,10mA~120A,PF≥0.5)
Fundamental active
power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
2-21 harmonic active
power:±0.02%(40V~576V,10mA~120A,PF≥0.5)
Display range:6 digital
display
-
Phase
measurement(phase difference between each phase voltage and
current)
Measurement error:±0.01°(40V~576V,10mA~120A)
Display
range:0.000°~359.999°
-
Power factor
measurement(each phase power factor and three phase power
factor)
Measurement
error:±0.0002(40V~576V,10mA~120A)
Display error:-1.00000 ~ 0 ~
+1.00000
-
Frequency
measurement
Measurement range:40~70Hz;
Measurement
error:±0.005%RD
Display error:40.0000Hz ~ 69.9990Hz
-
Harmonic content
measurement
Harmonic times:2-51( fundamental wave as 50Hz)
Harmonic
measurement error :±10%RD±0.1%(Rd as harmonic content reading)
Distortion
Measurement error :±10%RD±0.1%(Rd as distortion reading)
-
Energy
measurement
Measurement error:
Distorted wave active
energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
Sine reactive
energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
Sine active
energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
Fundamental wave active
energy:±0.02%(40V~576V,10mA~120A,PF≥0.5)
2-21 harmonic active
energy:±0.1%(40V~576V,10mA~120A,PF≥0.5)
Display
error:(0.00-999999)Wh,varh,VAh
-
Energy error
measurement
Tested meter constant
range:1~999999999999imp/kWh(kvarh,kVAh)
Pulse no. set
range:1~9999999
-
Tested energy pulse
input
Pulse electric level:5-12V
input Frequency:2MHz(max)
Min. pulse
width:250ns
Min. pulse interval:250ns
-
Standard energy
pulse output
Pulse electric level:5V±5%,100mA
Output frequency:Rated
frequency60kHz (while voltage,current limit, power factor as 1)
Max.
frequency: 72kHz(While voltage limit,1.2 current limit,power factor as
1)
-
Standard deviation
evaluated value
Voltage, current , active/reactive power, active/reactive
energy standard deviation evaluated
value≤0.002%
-
Variation caused by
influence quantity
Measurement circuit voltage influence:≤0.004%(Power supply
variation ±10%)
Measurement circuit frequency influence:≤0.004%(Power supply
variation ±10%)
Auxiliary power supply voltage influence:≤0.002%(Power supply
variation ±10%)
Auxiliary power supply frequency influence:≤0.002%(Power
supply variation±5%)
Auxiliary power supply phase
influence:≤0.002%
Reverse phase influence:≤0.002%
Current 3 times harmonic
influence:≤0.004%
AC external magnificent influence(1m,400
turns):≤0.01%
-
Temperature
Temperature
coefficient:≤0.0005% /°C
Self-heat influence:≤0.01%
Pre-heat
time:≤30min
-
24h
deviation:≤0.004%
-
Insulation
resistance:
The insulation between voltage,current input terminal and meter
cover,power supply terminal and meter cover should not less than
100MΩ
Industrial frequency withstand voltage:
Between
voltage,current input terminal & power supply terminal and meter cover
should withstand 50Hz sine wave 2kV 1min test;Between voltage circuit and
current circuit; difference phase of current circuit should withstand 600V test.
-
Ambient
Rated
temperature:23°C±2°C
Work temperature range:10°C~30°C
Max. work
temperature range:0°C~40°C
Storage and transportation max. temperature
range:-20°C~55°C
Relative humidity:≤85%
-
Others
Auxiliary power supply:
220V±15%,50Hz/60Hz ±10%
Power consumption: ≤30VA
Cabinet: 355mm×185mm× 145
mm
-
Weigh:
7.5kg