1 / 5
Basic Info
| Model No. | SCL-61H |
|---|---|
| Brand Name | Huizhong |
Product description
The ultrasonic water meter is suitable for use in residential,buildings and at district water supply sub-stations. ? Features: ? 1.?Large?dynamic?range?is?250. | Item | Parameter | ||||||
| Nominal Diameter.mm | DN15 | DN20? | DN25 | ||||
| Dynamic Range | 250 | ||||||
| Permanent Flow rate,? Q3(m3/h) | 1.6 | 2.5? | 1.6 | 2.5? | 4.0? | 4.0 | 6.3 |
| Overload Flow rate, Q4(m3/h) | 2.0? | 3.125 | 2.0 | 3.125 | 5.0 | 5.0 | 7.87 |
| Boundary Flow rate, Q2(L/h) | 10.24 | 16.0 | 10.24 | ?16.0 | ?25.6 | 25.6 | 40.32 |
| Minimum Flow rate, Q1(L/h)? | 6.4 | 10.0 | 6.4 | 10.0? | 16.0? | 16.0? | 25.2 |
| Starting Flow rate (L/h)? | 1.5 | 1.5 | 2.5 | 2.5 | 2.5 | 4.0 | 4.0 |
| Range of Pressure Loss | 25 | 63 | 10 | 25 | 63 | 25 | 63 |
| Medium | Water and other homogeneous fluids in full pipe flow | ||||||
| Accuracy | Class 2 | ||||||
| Max. Permissible working Pressure | 1.6Mpa | ||||||
| Working Environment | -25℃~+55℃,≤100%RH(If the range is exceeded, pls specify on ordering) | ||||||
| Temperature class | T30,T50,T70, default: T30 | ||||||
| Upstream Flow Field Sensitivity? | U10 | ||||||
| Downstream Flow Field Sensitivity | D5 | ||||||
| Climate &Mechanical Environmental Conditions Class | C | ||||||
| Electromagnetic Compatibility | E1 | ||||||
| Pushbutton | Photosensitive Key | ||||||
| Display? | Liquid Crystal8- digit +Prompting Characters | ||||||
| Content of Display | Cumulative flowrate: m3/h, Instantaneous flowrate:?m3/h, Water Temperature, ℃, Cumulative effective running time, h, Date: y/m/d, Clock: h/m/s, Software version, Screen test | ||||||
| Display Resolution | Cumulative flowrate: 0.001m3/h Water temperature: 0.01℃ | ||||||
| Display Range | Cumulative flowrate: 0 m3 ~+99999.999m3 | ||||||
| Type of Communication | Photoelectric Interface | Baudrate: 2400bps Protocol: EN13757 | |||||
| RS-485/M-BUS | Baudrate: 2400bps, 4800bps, 9600bps (Selectable) Default: 2400bps Transmission distance: ≤1200m Protocol: GJ/T188, Huizhong, Modbus, EN13757(selectable), Default: EN13757 | ||||||
| Radio Frequency | Transmission distance: 300m(open space) Frequency range:470MHz~510MHz | ||||||
| Data Storage | Storage of Cumulative flowrate in EMPROM on a month by month basis. Data can be kept within 100 years after the power failure. The data of past 24 months can be automatically stored. | ||||||
| Power Supply | Battery Powered DC3.6V(Service life >10 years) | ||||||
| Power Consumption | ??<0.2mW | ||||||
| Protection Class? | ??IP68 | ||||||
| Storage Temperature | -25℃~+55℃ | ||||||
| Power Cable length | 1.3m ? | ||||||
| Meter Mounting Position | On Water Supply Pipe | ||||||
Packaging & Shipping 10 sets in one box.
Our Services Our company provides OEM service, design and manufacture, buyer's label service. ? Quality Assurance ?
FAQ ?If you have any questions or requirements, please don't hesitate to contact with me at any time. Huizhong Instrumentation Co.,Ltd. ?www.hzyb.com? ? Alice Bai? ? ? Skype: alicebj69 ? Whatsap:+ 86 15032597010 ? ?Tel: + 86 315 3208504 Send your inquiry to this supplier