Remote reading RF module water meter iso 4064: ? 1.Application: Measuring the volume of cold potable water passing through the pipeline. ? 2.Mechanism?Parameters : Wet Type Measuring accuracy is up to Class B of ISO 4064 standard (GB/T 778-1996) Working Pressure </=1MPa Working Temperature max.30 centi dgree. ? 3. Technical Performance : ?
Model | Nominal Diameter | ? Benefit Ratio | Permanent Supply (Q3) | Transitional Supply (Q2) | Minimum Supply (Q1) | Minimum Reading | Maximum Reading |
mm | Q3/Q1 | Q2/Q1 | m3/h | m3 |
LXSZ-15(cold) | 15 | 80 | 1.6 | 2.5 | 0.05 | 0.03 | 0.00005 | 99999 |
LXSZ-20(cold) | 20 | 80 | 1.6 | 4.0 | 0.08 | 0.05 | 0.00005 | 99999 |
LXSZ-25(cold) | 25 | 80 | 1.6 | 6.3 | 0.13 | 0.08 | 0.00005 | 99999 |
LXSZR-15(hot) | 15 | 40 | 1.6 | 2.5 | 0.10 | 0.06 | 0.00005 | 99999 |
LXSZR-20(hot) | 20 | 40 | 40 | 4.0 | 0.16 | 0.10 | 0.00005 | 99999 |
LXSZR-25(hot) | 25 | 40 | 40 | 6.3 | 0.25 | 0.16 | 0.00005 | 99999 |
? ? 3. Electronic Parameters Working Frequency :470MHz Battery: 3.6V lithium battery , can be last 6 years Modulation: FSK Bandwith: 64kHz Power consumption: Low power consumption , 30uA Transmit Power : 50mW Transmit Distance : 200 meter open area. ? 4.?Product Features: * Mainly applicable to new contsruction projects, or reconstruction projects for old residential area which are inconvenient for wiring deployment. * Wireless transmission technology is applied to realize out-door meter reading, which simplified system installation by avoiding wiring deployment. * Friendly user interface for management software of backgrould platform. Variety of formats for data output and customized link with billing system according to customer's needs. * Total volume caculation of water flowing across the pipe and wireless meter reading. * Remote valve-control to solve arrearage problem * Three-stage automatic routing to increase transmission distance. * Real-time mete reading to realize ladder-type pricing. * Fully anti-water design , functional under the water. * ERFCU design, ultra-low power consumption * WOR remote awaking technology to reduce power consumption * Wamr Net routing protocol to ensure data security. * High speed transmission, data reading for single meter with 1.5 seconds. * Simple and practical structure with removable battery. ? 5. Production Line: ?

??

??

??

? 6. Package:

??

?

??

? ? 7. Installation:

??

?

??

?

??