Basic Info
| Model No. | KVVRP/KYFFRPJ/MKVV/MKVV22 |
|---|---|
| Brand Name | RiFeng |
Product description
Type | Name |
KVV | Copper Core PVC Insulation and Sheath Control Cable |
KVVR | Copper Core PVC Insulation and Sheath Control Flexible Cable |
KVVP | Copper Core PVC Insulation and Sheath Braided Shield Control Cable |
KVVRP | Copper Core PVC Insulation and Sheath Braided Shield Control Flexible Cable |
KVVP2 | Copper Core PVC Insulation and Sheath Copper Strips Shield Control Cable |
KVVP3 | Copper Core PVC Insulation and Sheath Aluminum Plastic Composite Belt Shield Control Cable |
KVVP2-22 | Copper Core PVC Insulation and Sheath Copper Strips Shield Steel Tape Armored Control Cable |
KVV22 | Copper Core PVC Insulation and Sheath Steel Tape Armored Control Cable |
KVV32 | Copper Core PVC Insulation and Sheath Thin Steel Wire Armored Control Cable |
Item | Code | Description |
Series Code | K | / |
Conductor Code | A/Ellipsis | 1 Class Conductor |
B | 2 Class Conductor | |
R | 5 Class Conductor (Soft Structure) | |
Insulation Code & Sheath Code | V | PVC Insulation and PVC Sheath |
Shield Code | P | Braided Shield |
P2 | Copper Strips Shield | |
P3 | Aluminum Plastic Composite BeltShield | |
Cover Layer Code | V | PVC Inner Sheath |
2 | Steel Tape Armoring | |
3 | Thin Steel Wire Armoring | |
2 | PVC Outer Sheath | |
Flame retardantcharacteristics code | ZA | General Flame Retardant Class A for Bind Burn |
ZB | General Flame Retardant Class B for Bind Burn | |
ZC | General Flame Retardant class C for Bind Burn | |
ZD | General Flame Retardant class D for Bind Burn | |
DDZA | Halogen Free Low Smoke Flame Retardant Class A for Bind Burn | |
DDZB | Halogen Free Low Smoke Flame Retardant Class B for Bind Burn | |
DDZC | Halogen Free Low Smoke Flame Retardant Class C for Bind Burn | |
DDZD | Halogen Free Low Smoke Flame Retardant Class D for Bind Burn |
AC. Rated Voltage | Working Temperature | Installation Temperature | Minimum bending radius | |
| Non- armored, non-copper tape shield | With Armored or Copper Tape Shield | |||
450/750 V | -35℃~70℃ | >0℃; <0℃ Preheat Needed; | ≥ 12 Times of Cable O.D. | ≥ 12 Times of Cable O.D. |
Type | Rated voltage V | Nominal Cross Section of Conductor (mm2) | |||||||||||
0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||||||
No. of Cores | |||||||||||||
| KVV KVVP | 450/750 | — | 2~61 | 2~14 | 2~10 | ? | |||||||
KVVP2 | — | 4~61 | 4~14 | 4~10 | ? | ||||||||
KVV22 | — | 7~61 | 4~61 | 4~14 | 4~10 | ? | |||||||
KVV32 | — | 19~61 | 7~61 | 4~14 | 4~10 | ||||||||
KVVR | 2~61 | — | — | ||||||||||
KVVRP | 2~61 | 2~48 | — | — | |||||||||
| ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? | ? |
Item | Unit | Parameter | |||||||||
No. of Cores | - | 2~61 | |||||||||
Conductor Cross Section | mm2 | 0.5 | 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
| Conductor DC resistance at 20℃ ≤ | Class 1 or 2 conductor | No tinning | Ω/km | 36.0 | 24.5 | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 |
Tinning | 36.7 | 24.7 | 18.2 | 12.2 | 7.56 | 4.61 | 3.08 | 1.84 | |||
Class R conductor | No tinning | 39.0 | 26.0 | 19.5 | 13.3 | 7.98 | - | - | - | ||
Tinning | 40.1 | 26.7 | 20.0 | 13.7 | 8.21 | ? | ? | - | |||
| Insulation resistance at 70℃ ≥ | Class 1 Conductor | MΩ·km | 0.013 | 0.012 | .011 | .011 | .011 | .010 | .010 | - | |
Class 2 Conductor | 0.014 | 0.014 | .013 | .011 | .010 | .009 | .009 | 0.0065 | |||
Class R Conductor | 0.013 | 0.011 | .010 | .010 | .010 | - | - | ? | |||
Insulation Resistance at 20℃ | MΩ·km | ≥10 | |||||||||
Test voltage 50Hz | V, min | 3kV,5min | |||||||||
Flame Retardant Characteristics | - | Class A, B According to IEC 60332-3 | |||||||||
Low Halogen Low Smoke Characteristics | - | HCl≤100mg/g; Pervious Light Rate≥30% | |||||||||
Flame retardant and low halogen low smoke characteristics are available as request of consumers. | |||||||||||