1. High-performance travel limiter realizes control from Vg min to Vg Max. The three valves are integrated into a valve body, which has a small volume and a comprehensive control method. As the control current increases, the pump is adjusted to a larger displacement.
2. The pressure cut-off valve is a sequence valve. When the load pressure reaches the opening pressure of the shut-off valve, the opening of the valve will open.
3. The constant power valve starts from the control starting point of the set range. The output power of the hydraulic pump is constant.
Technical characteristics
Good opening and closing characteristics ensure stable pump pressure and energy saving
Power pressure setting range: 5-32mpa pressure cut-off setting range: 5-35mpa load sensitive pressure difference range: 1.4-2.5mpa, standard setting value is 1.8mpa
Good opening and closing special control valve
Constant power control valve
Sequence control valve

Specifications
Power pressure setting range Control current Industrial resistance Jitter frequency
Pressure cut off setting range Voltage
5-32MPa 5-35MPa 24V Initial value 200mA, control termination value 600mA at Vgmin 22.7Ω 100Hz