1. High-quality high-performance travel limiter realizes the control from Vg min to Vg Max. These three valves are integrated in the valve body, the valve body is small, and the control method is comprehensive. As the control current increases, the pump is adjusted to a larger displacement.
2. The pressure cut-off valve is a sequence valve. When the load pressure reaches the opening pressure of the shut-off valve, the opening of the valve will open.
3. The constant power valve starts from the control starting point of the set range. The output power of the hydraulic pump is constant.
Technical characteristics
Good opening and closing characteristics ensure stable pump pressure and energy saving
Power pressure setting range: 5-32mpa pressure cut-off setting range: 5-35mpa load sensitive pressure difference range: 1.4-2.5mpa, standard setting value is 1.8mpa
Good control valve for opening and closing
Constant power control valve
Sequence control valve
Specifications
Power pressure setting range Control current Industrial resistance Jitter frequency
Pressure cut off setting range Voltage
5-32MPa 5-35MPa 24V Initial value 200mA, control termination value 600mA at Vgmin 22.7Ω 100Hz